Configuration scheme of ADS1298 and ADS1252 for typical ECG acquisition system

An Kang, Si Junfeng, Liu Hongxing, Huangxiaolin, Zhao YingLiang Yonggang

Journal of Nanjing University(Natural Sciences) ›› 2014, Vol. 50 ›› Issue (2) : 154.

PDF(837478 KB)
PDF(837478 KB)
Journal of Nanjing University(Natural Sciences) ›› 2014, Vol. 50 ›› Issue (2) : 154.

Configuration scheme of ADS1298 and ADS1252 for typical ECG acquisition system

  • An Kang, Si Junfeng, Liu Hongxing, Huangxiaolin, Zhao YingLiang Yonggang
Author information +
History +

Abstract

ADS1298 and ADS1252 are two wonderful ICs issued by TI company, which can be used for bioelectricity acquisition system. In this paper, the mechanisms of sampling configuration of the two ICs are summarized first. For ADS1298 configuration, there are two first-time sampling modes to be selected, one is high-precision mode with the first-time sampling rate 512 kHz, and the other is the low-power mode with its first-time sampling rate 256 kHz; then a low-pass filter is configured with an order parameter N, and its frequency response is of SINC type function. For ADS1252, the external clock is divided by 6, getting the first-time sample rate, and then also a SINC low-pass filter is used with a fixed order parameter 64. After filtering, for both ICs, a resampling process with certain rate is performed, and then the final data are output to us for collection. On basis of these, the specific sampling configuration schemes for typical ECG acquisition systems with the two ICs are proposed, and the corresponding performance are simulated. ADS1298 is configured to a high-precision mode, its resampling parameter N is configured with 1024, and ADS1252’s system clock is set as 0.192 MHz, so that both ICs can get the same final sampling rate of 500 Hz. The paper also built a real typical ECG acquisition system with ADS 1298 and C8051F320 configured using the proposed scheme, which has been able to acquire the real ECG signals. After test, basically, the amplitude frequency response of the real system is consistent with the simulated result. It is believed that this work is useful for the sampling configuration of the two ICs when used in bioelectricity acquisition applications

Cite this article

Download Citations
An Kang, Si Junfeng, Liu Hongxing, Huangxiaolin, Zhao YingLiang Yonggang. Configuration scheme of ADS1298 and ADS1252 for typical ECG acquisition system[J]. Journal of Nanjing University(Natural Sciences), 2014, 50(2): 154

References

[1] 林 凌,刘近贞,张 昊等. 基于过采样的多种生物信息同步数据采集电路.仪表技术,2011(10):[2] 李 刚,张丽君,林 凌等. 利用过采样技术提高ADC测量微弱信号时的分辨率.纳米技术与精密工程,2009,(1):[3] 何炳林,张焕文,梁柱扬等. 基于ADS1252的数据采集模块设计.现代电子技术,2011(13):139~148.
[4] 魏厚杰,官金安,方 浩. ADS1298模拟前端的便携式生理信号采集系统.新器件新技术,2012(2):36~39.
[5] 秦 伟,陈军波,陈心浩. 经母体腹部提取胎儿心率信号的系统设计.现代科学仪器,2012(2):40~44.
[6] Zhang Y H,Sun G G,Yang Y C.12-lead ECG data acquisition system based on ADS1298.?Procedia Engineering,2012,?29: 2103~2108.
[7] Freed A,Chan A D, Lemaire E D, et al. Wearable EMG analysis for Rehabilitation (WEAR)-Surface electromyography in clinical gait analysis. In?Medical Measurements and Applications Proceedings (MeMeA), 2011 IEEE International Workshop on?(pp. 601-604). IEEE.
[8] Aksenov E V, Ljashenko Y M, Plotnikov A V, et al.?Biomedical data acquisition systems based on sigma-delta analogue-to-digital converters. Moscow State Inst of Electronic Technology (RUSSIA), 2001.
[9] Gupta S K, Mathew S K, Venkatakrishnan P. Development of solar scintillometer.?Journal of Astrophysics and Astronomy,?2006,27(2-3): 315~320.
[10] TI. ADS1298 Datasheet[EB/OL]. [2012-02]. http://www.ti.com.cn/cn/lit/ds/zhcs313i/zhcs313i.pdf
[11] TI. ADS1252 Datasheet[EB/OL]. [2006-06]. http://www.ti.com.cn/cn/lit/ds/sbas127d/sbas127d.pdf
[12] 胡广书.数字信号处理:理论、算法与实现.北京:清华大学出版社,2003: 412
[13] 陈蕴, 宁新宝. 微电脑控制的心电数据床边采集系统南京大学学报自然科学, 2002, 38(1): 14-19.
[14] 宁新宝, 李德华, 丁宋威等. 12导同步心电图波形检测与识别的研究南京大学学报自然科学, 2004,40(1): 129~136.
[15] 刘琚,何振亚. 利用高阶累积量和独立分量分析网络进行盲均衡与系统辨识数据采集与处理, 1998,13(3): 201205
PDF(837478 KB)

2170

Accesses

0

Citation

Detail

Sections
Recommended

/